EXTENDABLE FLOODLIGHTS DO NOT OPERATE - Continued
EXTENDABLE FLOODLIGHTS DO NOT OPERATE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  401    402    403    404    405  406  407    408    409    410    411  
img
DRAFT
TM 5-4210-249-13&P-2
0158
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04502
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 13.
Put PASS FLOOD switch to ON position (WP 0004). Check for continuity across PASS
FLOOD switch from terminal 5 to terminal 6.
a.
If continuity is present, repair wire 1147 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0440).
b.
If continuity is not present, replace PASS FLOOD switch (WP 0315).
0158-9