SIREN DOES NOT OPERATE PROPERLY - Continued
SIREN DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  252    253    254    255    256  257  258    259    260    261    262  
img
DRAFT
TM 5-4210-249-13&P-2
0150
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03833
NOTE
Integrated siren control amplifier will produce a faint audible signal which can be heard at
siren control even if siren speaker or wiring leading to siren speaker fails.
Step 8.
Reconnect cab power distribution wire harness siren control connector MP2. Remove
skid plate grille (WP 0550). Disconnect main wire harness main 3 connector. Turn
battery disconnect switch to ON position (WP 0007). Put EMERG MASTER switch to
on position (WP 0004). Put siren control selector switch to WAIL, YELP, and HI-LO,
one position at a time (WP 0004). Check if siren output can be heard at siren control.
If siren can be heard at siren control, go to Step 15.
0150-6