DRAFT
TM 5-4210-249-13&P-2
0130
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02960
Step 27.
Turn Service Drive Lights Off (TM 9-2320-347-10). Turn battery disconnect switch to
OFF position (WP 0007). Close all stowage compartment doors and hatches except
non-operating door (WP 0010). Remove door switch at non-operating door (WP 0385).
Do not disconnect wires. Check for continuity between door switch terminal wire 1609
(gray) and a known good ground when switch is closed (door switch is not pressed).
If there is no continuity, go to Step 30.
NOTE
If wire 2740 cannot be identified at door switch, measure continuity across switch from
terminal wire 1609 (gray) to both black wire terminals. Continuity should be measured
between all terminals, when switch is closed (door switch is not pressed).
Step 28.
Check for continuity across door switch between terminal wire 1609 (gray) and terminal
wire 2740 (black) when switch is closed (door switch is not pressed).
If there is no continuity, replace door switch (WP 0385).
0130-20