MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04054
Step 38.
Remove crew cab access panel (WP 0499). Remove pump house panel Q (WP 0540).
Disconnect main wire harness pump operator's panel wire harness connector DO2.
With a test lead set, check for continuity across main wire harness wire 2855 (red) from
main wire harness pump operator's panel wire harness connector DO2, terminal 13 to
pump operator's panel TANK TO PUMP switch.
If there is no continuity, repair wire 2855 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).