TANK-TO-PUMP VALVE(S) DOES NOT OPERATE PROPERLY - Continued
TANK-TO-PUMP VALVE(S) DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  945    946    947    948    949  950  951    952    953    954    955  
img
.
DRAFT
TM 5-4210-249-13&P-1
0119
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04019
Step 24.
Turn battery disconnect switch to OFF position (WP 0007). Check for continuity across
cab power distribution wire harness wire 2844 (white) from relay 12 connector, terminal
4 to relay 11 connector, terminal 3.
a.
If there is continuity, replace relay 12 (WP 0402).
b.
If there is no continuity, replace cab power distribution wire harness
and block (WP 0441).
0119-18