DRAFT
TM 5-4210-249-13&P-1
0119
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04010
Step 13.
Remove crew cab access panel (WP 0499). Remove pump house panel Q (WP 0540).
Disconnect main wire harness pump operator's panel wire harness connector DO2.
With a test lead set, check for continuity across main wire harness wire 2770 (blue)
from main wire harness pump operator's panel wire harness connector DO2, terminal
15 to main wire harness main 5 wire harness connector, terminal 18.
a.
If there is continuity, repair wire 2770 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
b.
If there is no continuity, repair wire 2770 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
0119-9