MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03454
Step 7.
Disconnect cab pump control wire harness cab power distribution wire harness
connector. With a test lead set, check for continuity across cab pump control wire
harness wire 4038 (brown) from PUMP COOLER switch connector, terminal 4 to cab
pump control wire harness connector, terminal 16.
a.
If there is continuity, repair wire 4038 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
b.
If there is no continuity, repair wire 4038 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0443).