• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CREW CAB AIR CONDITIONER/HEATER DOES NOT OPERATE PROPERLY - Continued
CREW CAB AIR CONDITIONER/HEATER DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  313    314    315    316    317  318  319    320    321    322    323  
img
. . . .
DRAFT
TM 5-4210-249-13&P-1
0070
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT 4812A
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 39.
Put crew cab air conditioner/ heater control panel switch to off position (WP 0008). Turn
battery disconnect switch to OFF position (WP 0007). Remove crew cab air
conditioner/heater assembly cover (WP 0200). Disconnect crew cab air conditioner/
heater blower motor red wire connector. Turn battery disconnect switch to ON position
(WP 0007). Put crew cab air conditioner/heater control panel switch to on position
(WP 0008). With a test lead set check for 22 to 28 VDC at red wire from crew cab air
conditioner/heater blower motor wire harness connector to a known good ground.
If 22 to 28 VDC are not present, go to Step 41.
0070-23