PREPARATION FOR STORAGE OR SHIPMENT - Continued
PREPARATION FOR STORAGE OR SHIPMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  177    178    179    180    181  182  183    184    185    186    187  
img
DRAFT
TM 5-4210-249-13&P-1
0043
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00528P
27. Lift power switch guard (53) and put POWER switch (54) to | (on) position. Indicator light (55) will illuminate.
28. Push and release agent discharge button (56) on front of joystick control handle (57) to begin discharge.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00529P
29. Put WINDSHIELD DELUGE switch (58) to on position, and discharge water for 15 to 30 seconds.
NOTE
All valves should be left open for up to 24 hours, to allow for evaporation of water from
system.
30. Push and release agent discharge button (56) on front of joystick control handle (57) to stop discharge.
31. Put POWER switch (54) to
(off) position indicator light (55) will go out.
0043-7