WATER TANK FILL - Continued
WATER TANK FILL - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  89    90    91    92    93  94  95    96    97    98    99  
img
DRAFT
TM 5-4210-249-13&P-1
0020
FILLING FROM DRAFT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 11
When backing up vehicle, one crew member must be in back of vehicle operating
rear step buzzer to communicate with driver. Failure to comply may result in
damage to equipment or injury or death to personnel.
NOTE
Pump performance is maximized with less than a 10 ft. (3 meters) vertical lift. As vertical
lift increases above 10 ft. (3 m), maximum pump capacity will be reduced. Altitude also
affects pump performance.
All valves, drain valves, and caps should be closed.
1.
Position vehicle as close to water source as possible.
2.
Park vehicle (TM 9-2320-347-10).
TFFT00593P
CAUTION
Ensure suction hose strainer is clean and free from debris and obstructions.
Failure to comply may result in damage to equipment.
3.
Connect suction hose strainer (1) to suction hose (2).