TM 5-4210-233-14&P-1
4-207. AUXILIARY POWER UNIT - Continued
(6)
Connect wire #1 674 to terminal #2 of decompression solenoid relay (6).
(7)
Secure one yellow and one green cable with mounting nut (5).
(8)
Secure black cable to white wires #1 and #3 with wire nut (4).
(9)
Install control box cover (3) and four screws (2).
(10)
Connect exhaust pipe (1).
c.
Follow-on Maintenance.
(1)
Install APU air cleaner (see para 4-213).
(2)
Connect batteries (see para 4-114).
4-519
|