TM 5-4210-233-14&P-1
4-116. BATTERY CHARGE RECEPTACLE
This task covers:
a.
Removal
c.
Installation
b.
Cleaning and Inspectiond.
Follow-on Maintenance
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12.)
(Appendix B, Section III, Item)
APU Shutdown (see para 2-16.)
Batteries Disconnected (see para 4-114.)
MATERIALS/PARTS REOUIRED
Emery Cloth (Item 25, Appendix E)
a.
Removal.
(1) Remove two bolts (1), washers (2), and
lockwashers (3).
(2) Tag and disconnect wiring harness.
(3) Remove receptacle (4) and gasket (5).
b.
Cleaning and Inspection.
(1) Inspect for broken or cracked receptacle. If
damaged, replace.
(2) Inspect wiring for fraying or cracked
insulation. If wiring is damaged, contact
Direct Support Maintenance.
(3) Inspect socket, contacts, and wiring for
corrosion. Clean corrosion with emery
cloth (Item 25, Appendix E). If corrosion
cannot be removed, replace receptacle
and/or wiring.
c.
Installation.
(1) install gasket (5).
(2) Connect wiring harness to receptacle with
butt splice (Item 27, Appendix E).
(3) Install receptacle (4) and fasten with two
bolts (1), washers (2), and lockwashers (3).
d.
Follow-on Maintenance.
(1) Connect batteries (see para 4-114.).
4-370
|