| |
TM 5-4210-233-14&P-1
4-55. FOAM TANK DRAIN VALVE-Continued
e.
Installation.
(1)
Coat two O-rings (6) with silicone grease (Item 11, Appendix E) and install on valve (1).
(2)
Position valve (1) between flanges (2).
(3)
Install and tighten four short bolts (3) and four long bolts (4).
(4)
Remove four long bolts (4).
(5)
Position valve (1) in brackets (5).
(6)
Install and tighten four long bolts (4).
f.
Follow-on Maintenance.
(1)
Install curbside operator's panel (see para 4-26).
(2)
Connect batteries (see para 4-114).
4-272
|