TM 5-4210-233-14&P-1 4-2.  Unit Troubleshooting-Continued MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION ELECTRICAL SYSTEM - APU AND 110-VOLT CIRCUITS - Continued 5DRIVERS/PASSENGERS FLOODLIGHT (11 OV) DOES NOT ILLUMINATE WITH CAB SWITCH AND AUXILIARY POWER UNIT RUNNING - Continued Step 4.  Check relay inside service panel for proper operation. Replace relay (see para 4-9.4). Step 5.  Check for +12V at circuit breaker #14 at batteryaccessory buss. Replace breaker (see para 4-99). Step 6.  Check wiring for continuity. Replace wire (see para 4-9.4). 6 NO POWER AT ANY 11OV OUTLET (EXCEPT LADDER TIP) (Refer to Electrical Wiring Diagrams, Appendix H, Sheet 15 of 16.) Step 1.  Check outlet. Replace outlet (see para 4-117). Step 2.  Check breaker. Reset/replace breaker (see para 4-119). Step 3.  Check auxiliary power unit for proper operation. Refer to auxiliary power unit test procedure (see Chapter 6). Step 4.  Check writing for continuity. Replace wire (see para 4-9.4). 4-144

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business