5-60. EMERGENCY HYDRAULIC PUMP AND MOTOR - Continued
b. Installation.
NOTE
Note position and orientation of ports on pump to ensure correct
positioning at reassembly.
(1)
Install pump (5) on motor (2) and install four bolts (8) with lockwashers (9).
(2)
Position pump and motor assembly on mounting bracket with pump facing front of truck. Install two
bolts (6) with lockwashers (7) to secure motor (2) to mounting bracket.
(3)
Connect two hoses (3 and 4) to pump (5).
(4)
Connect electrical cable (1) to top of motor (2).
c.
Follow-on Maintenance
(1)
Fill hydraulic oil tank (see para 5-48).
(2)
Connect batteries (see para 4-114).
(3)
Turn battery selector switch in cab to on position (1, 2 or both).
(4)
See paragraph 2-15 and test operation of emergency hydraulic pu p. Check for leaks and tighten
m
connections as necessary.