Click here to make tpub.com your Home Page

Page Title: Removal
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-4210-233-14&P-1
4-209. APU ANTI-FLICKER POINTS AND RESISTOR - Continued
b. Removal.
(1) Remove plunger diaphragm (6), plunger guide (7) and plunger (8).
(2) Remove point set (9).
(3) Replace O-ring seal (1 0).
c. Installation.
(1) Install point set (9), plunger (8), plunger guide (7)
and plunger diaphragm (6).
(2) Adjust point gap to .025" (.64 mm). See para a. above.
(3) Install wire (4), anti-flicker cover (3), lockwasher (2)
and screw (1).
d. Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
4-523

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business