|
|
TM 5-4210-233-14&P-1
4-209. APU ANTI-FLICKER POINTS AND RESISTOR - Continued
b. Removal.
(1) Remove plunger diaphragm (6), plunger guide (7) and plunger (8).
(2) Remove point set (9).
(3) Replace O-ring seal (1 0).
c. Installation.
(1) Install point set (9), plunger (8), plunger guide (7)
and plunger diaphragm (6).
(2) Adjust point gap to .025" (.64 mm). See para a. above.
(3) Install wire (4), anti-flicker cover (3), lockwasher (2)
and screw (1).
d. Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
4-523
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |