4-203. MONITOR AND NOZZLE CONTROLS
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12 .)
(Appendix B, Section III, Item 1)
APU Shutdown (see para 2-16 .)
Batteries Disconnected (see para 4-114 .)
a. Removal
(1) Remove four screws (1) and cover (2).
(2) Tag and disconnect wires from switch to be replaced.
(3) Remove hex nut with boot (3), lockwasher (4) and switch (5).
b. Installation.
(1) Put switch (5) in position and install lockwasher (4) and hex nut with boot (3).
(2) Connect wires to switch (5) and remove tags.
(3) Install cover (2) with four screws (1).
c. Follow-on Maintenance.
(1) Connect batteries (see para 4-11 ).
(2) Test operation of switch.
4-511