4-183. FLOW MINDER
THIS TASK COVERS:
a. Removal
c. Follow-on Maintenance
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12.)
(Appendix B, Section IlI, Item 1)
APU Shutdown (see para 2-16.)
Batteries Disconnected (see para 4-114.)
a. Removal.
(1) Remove four screws (1) and one locknut (2).
NOTE
Locknut (2) retains AUDIO ALERT buzzer ground wire.
(2) Tag wires.
(3) Loosen knurled ring (3) and remove yellow wire (4)
(4) Loosen knurled ring (5) and remove orange wire (6).
(5) Remove flow minder (7).
b. Installation.
(1) Install orange wire (6) and tighten knurled ring
(5).
(2) Install yellow wire (4) and tighten knurled ring
(3).
(3) Install flow minder (7) in panel.
NOTE
Locknut (2) retains AUDIO ALERT buzzer ground
wire.
(4) Install four screws (1).
(5) Connect AUDIO ALERT ground wire to screw (1)
and secure with locknut (2).
c.
Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
(2) Operate aerial discharge and check operation
of flow minder (see para 2-13).
4-473