4-117. 110 VAC, 60 HZ RECEPTACLES
This task covers:
a. Removal
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12.)
(Appendix B, Section III, Item 1)
APU Shutdown (see para 2-16.)
a. Removal.
NOTE
There are five receptacles, two on each side of hose
body, and one at the ladder tip.
(1) Remove screws (1), face plate (2) and face
plate gasket (3).
(2) Remove screws (4) and carefully remove
receptacle (5) from panel (6).
(3) Loosen screws (7) on back of receptacle (5) and
tag and disconnect three wires (8).
b. Installation.
(1) Connect new receptacle (5) to wires (8) as
tagged. Secure with screws (7) on back of
receptacle (5).
(2) Install receptacle (5) on panel (6) using screws
(4).
(3)
Install gasket (3) and face plate (2) on
receptacle (5) using screws (1). Make sure face
plate gasket (3) is flat and pulled tight against
panel.
(4) Start APU (see para 2-16) and test 110V
receptacles.