TM 5-4210-233-14&P-1
4-77. CAB DOORS-Continued
(10)
To remove window regulator (28), remove nut (29) and bolt (30) from horizontal slide track (31).
(11)
Remove two screws (32), lockwashers (33) and nuts (34) securing regulator (28) to bracket (28A)
inside door.
(12)
Remove three screws (35), nuts (36) and washers (37) securing regulator mounting bracket to
edge of door.
(13)
To remove paddle lock (45), remove cotter pin (38), clevis pin (39), two washers (40) and
cable (41).
(14)
Remove nut (42) from striker (43). Remove bracket (44) and paddle lock (45).
(15)
To remove rotary lock (47), remove cotter pin (48), washers (49), clevis pin (50) and two cables
(41 and 13).
(16)
Remove four nuts (51) and screws (52).
(17)
Remove rotary lock (47).
c.
Cleaning and Inspection.
(1)
Clean all internal door parts.
(2)
Inspect window for cracks or damage. If damaged, replace window (see para 4-78).
(3)
Inspect for broken, cracked or corroded parts. If damaged, replace.
(4)
Inspect cables for cuts or fraying. If damaged, replace.
(5)
Apply a light coat of silicone grease (Item 11 Appendix E) to all internal moving parts and the door
latch.
d. Assembly.
(1)
Align rotary lock (47) in door and secure with four nuts (51) and screws (52).
(2)
Attach two cables (41 and 13) to door latch (47) with clevis pin (50), two washers (49) and cotter
pin (48).
(3)
Install paddle lock (45) in door. Install bracket (44) and install nut (42) on striker (43).
(4)
Install cable (41) with clevis pin (39), washers (40), and cotter pin (38).
(5)
To install window regulator bracket (28A), align in door and fasten to door frame edge with three
screws (35), washers (37) and nuts (36).