BODIES AND CABS
charging of the air conditioning system.  Use of this tool also
permits   purchase   of   refrigerant   in   large,   economical   drum
containers.
Fig.  28   Heated Charging Cylinder (SE-2448)
Electronic Refrigerant Leak Detector (Audible Type)
The SE-2449 Refrigerant Leak Detector (Fig.  29) is
used  to  check  for  refrigerant  leaks  throughout  the  entire  air
conditioning system.  When this detector senses a refrigerant
leak, an audible signal (sound) is emitted.
Fig.  29   Electronic Refrigerant Leak Detector -Audible Type
(SE-2449)
Electronic Refrigerant Leak Detector (Visual Type)
The  SE-2272  Refrigerant  Leak  Detector  (Fig.    30)
has  the  leak  sensor  and  a  neon  signal  light  mounted  in  a
probe.    When  the  probe  encounters  a  refrigerant  leak,  the
signal light blacks-out.  The neon lamp glows steadily if a leak
is not present.
Fig.  30   Electronic Refrigerant Leak Detector -Visual Type
(SE-2272)
Refrigerant Can Adapter Valve
The   SE-2450   Refrigerant   Can   Adapter   Valve   (Fig.
31)  is  used  to  connect  either  flat  top  or  screw  top  type  one-
pound refrigerant containers to the manifold and gauge set for
charging or adding refrigerant to the air conditioning system.