4-51. INVERTER RECEPTACLES REPLACEMENT
This task covers:
a.
Removal
b. Installation
INITIAL SET-UP
Tools
General Safety Instructions
General Mechanics Tool Kit
Battery Selector Switch OFF.
Battery Cables Disconnected.
Materials/Parts
Inverter Receptacle (5800)
Gasket (NSS)
REMOVAL
INSTALLATION
a.
Remove screw (1) securing cover (2) to receptacle
box (3). Remove cover (2) and gasket (4).
b.
Remove two screws (5) securing receptacle (6) to
box (3).
c.
Carefully remove receptacle (6) from box (3) and
loosen three screws (7) securing wiring to recepta-
cle (6).
d.
Remove four screws (8) securing receptacle box
(3) to body and lower box (3).
e. Disconnect wiring.
f. Loosen two screws (9) on clamp (10) and remove
wire from box (3).
a.
Insert wire into box (3) and secure clamp (10) over
wire using two screws (9).
b.
Connect wiring.
c.
Secure box (3) to body using four screws (8).
d.
Attach wires to receptacle (6) and secure with three
screws (7).
e. Secure receptacle (6) to box (3) using two screws
(5).
f. Install new gasket (4) and cover (2) and secure with
screw (1).
g. Connect battery cables.
4-66
|