TM5-4210-229-14&P
4-48. REAR QUARTZ FLOOD LIGHT MAINTENANCE (Continued).
REMOVAL
a.
Remove two setscrews (1) on clamp (2).
b.
Remove three setscrews (3) on collar (4).
c.
Lift quartz light assembly (5) out of fire body.
d.
Remove four locknuts (6) and screws (7) along
with the clamp (2).
e.
Remove three locknuts (8) and screws (9) and re-
move tube assembly (10) from fire body.
f.
Remove four locknuts (11) and screws (12).
g.
Remove collar (4) and gasket (13) from fire body.
REPAIR
a.
Remove two screws (14) and hinge open lens
cover (15).
b.
Open clip (16) and remove bulb (17).
c.
Insert new bulb (17) and close clip (16).
d.
Close lens cover (15) and secure with screws (14).
e.
Connect battery cables.
INSTALLATION
a.
Install collar (4) and gasket (13) onto fire body and
secure with four screws (12) and locknuts (11).
b.
Insert tube assembly (10) into body and secure
with three screws (9) and locknuts (8).
c.
Position clamp (2) onto body and secure with four
screws (7) and locknuts (6).
d.
Insert quartz light assembly (5) into fire body.
e.
Insert three setscrews (3) into collar (4).
f.
Insert two setscrews (1) into clamp (2).
g.
Install inverter receptacles (paragraph 4-51).
h.
Connect battery cables.
4-63
|