TM 5-4210-224-14&P
4-190. FIRE PUMP PROPELLOR SHAFT REPLACEMENT. (Continued)
REMOVAL
a. Remove screw (1) from slip yoke (2) on PTO
end of propellor shaft (3).
b. Remove four retaining rings (4) from universal
joint on PTO end.
c. Remove bearing (5) from universal joint on PTO
end of propellor shaft (3).
d. Remove four retaining rings (4) from universal
joint on pump end of propellor shaft (3).
e. Remove bearing (6) from slip yoke (7) on pump
shaft (8) while supporting propellor shaft (3).
c. Install propellor shaft (3) onto bearing (6).
f. Remove propellor shaft (3).
d. Install PTO and slip yoke (2) on PTO shaft.
g. Remove pump side slip yoke (7).
e.
Install bearing (5) into slip yoke (2) on PTO
shaft.
INSTALLATION
f. Install propellor shaft (3) onto bearing (5).
a. Install pump side slip yoke (7) on pump shaft (8).
g. Secure PTO end slip yoke (2) to PTO shaft with
b. Install bearing (6) in slip yoke (7).
screw (1).
4-260
|