2-26. FILLING WATER TANK FROM HYDRANT OR PRESSURE SOURCE.
NOTE
Filling from hydrant requires the use of a 2 1/2 inch hose and suitable couplings.
a. Open tank fill cover.
b. Remove cap and connect 2 1/2 inch hose with adapter to 3 inch suction inlet connection (17, figur 2-1) on the
street side operator's control panel.
c. Connect hose to hydrant outlet.
d. Using hydrant wrench, open hydrant supply.
e. Open 3 inch suction inlet control handle (16, figure 2-1).
f. Open tank fill control handle (14, figure 2-1). Monitor display on water tank level gauge (19) on street side
operator's control panel.
g. Shut off hydrant supply when tank is filled. Close tank fill control handle (14, figure 2-1).
h. Close 3-inch suction inlet control handle (16, figure 2-1).
NOTE
Some water spillage will occur when hose is disconnected as the water in the fill line drains out.
i. Disconnect hose from hydrant. Install cap on 3-inch suction inlet connection (17, figure 2-1).