2-13.13 Bearing Housing Repair - Continued
(8) Slide revolution counter gear (33) onto shaft (38). Make sure the socket screw hole is at the upper end.
(9) Rotate revolution counter gear (33) until the socket screw hole alines with groove in pump shaft (38).
(10) Install socket screw (32) into revolution counter gear flange. Do not fully tighten.
(11) Slide oil finger (31) onto pump shaft (38) up to the revolution counter gear flange.