TM 5-4210-220-12
1-10. EQUIPMENT DATA. - Continued
p. Cooling System
Radiator
Make .......................................................................................................Heatex Howden Inc
Type ............................................................ Fin and Tube (Includes Transmission oil cooler)
Frontal Area
....................................................................................................... 1397.0 sq in. (0.90 sq m.)
Capacity (Including Engine) ................................................................................................15.2 gal (57.5 L)
Engine Fan
................................................................................................ On 195 deg. F, Off 190 deg. F
(90 deg. C)
(88 deg. C)
Radiator Shutters .................................................................................. Open 190 deg. F, Close 185 deg. F
(88 deg. C)
(85 deg. C)
q. Electrical System.
Type
....................................................................................................... 12-volt negative ground
Protection
.........................................................................................Automatic thermal reset breakers
Batteries
Make .......................................................................................................................... Delco
Model .......................................................................................................................... 1150
Number of Batteries .............................................................................................................................. Four
Alternator
Make ......................................................................................................................... Delco
Model ..........................................................................................................................27-SI
Output ................................................................................................ each 80 amp 12 Vdc
Number of Units ............................................................................................................Two
r. Firefighting System
Agent Tanks
Construction ................................................................................................ Stainless Steel
Water Tank Capacity ...............................................................................660 gal (2500 L)
Foam Tank Capacity ....................................................................................72 gal (273 L)
Fill/Inspection Hatches Make ...................................................................... Betts Industries
Fire Pump
Make ............................................................................................................................Godiva
Model ................................................................................................................... UFPX 664/1
Type ................................................................................................... Single stage Centrifugal
Oil Capacity ........................................................................................................ 0.7 qt (0.7 L)
Pumping Rate ........................................... Structural mode 1000 gpm at 150 psi (3790 L/min)
CFR mode 600 gpm at 250 psi (2270 L/min)
Foam Proportioners
Make .......................................................................................................... Feecon
Model ......................................................................................................HCAP 1.5
Metering Control .............................................................................Multiple Orifice
Metering Percentage ............................................................................. 0.1 to 10%
1-22
|