TM 5-4210-220-12
4-13 PUMP BODY - Continued
REPAIR
a. Door Lock Handle Repair
NOTE
Identical door lock handles are
used on all three pump body
doors. The following repair
procedure applies to any door.
Door lock handle is non-
repairable. If defective it must be
replaced.
(1)
Remove four screws (1) and locknuts (2)
and remove handle (3).
(2)
Clean residual sealant from edge of door
panel.
(3)
Apply a 1/8 in. (3 mm) bead of sealant
(item 25, Appendix E) to contact surface
of new door lock handle (3).
(4)
Install lock handle using screws (1) and
new locknuts (2). Tighten nuts firmly.
b.
Location Pin Repair.
NOTE
This procedure is only applicable
to the pump panel door.
(1)
Remove locknuts (1 and 2) and pin (3).
(2)
Inspect pin. Replace if thread is damaged
or stripped.
(3)
Install pin (3) using new locknuts (1 and
2).
(4)
Adjust nuts until pin extends 1/4 in. (6
mm) below edge of door panel as shown.
Tighten nuts firmly.
4-129
|