TM 5-4210-220-12
Table 4-2 UNIT TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8n
FAST AIR NOT TRANSFERRING TO PRIMARY AIR WHEN IGNITIO N TURNED ON. PRIMARY
AIR IN ALARM FOR MORE THAN 5 SECONDS AFTER IGNITION ON
Step 1
Check air starter valve on fast air tank
Repair as required, (see para. 4-22)
Step 2
Check for leaks on fast air reservoir
Repair hoses/ connectors, replace tank or close drain valve
Step 3
Solenoid valve operation on fast air tank
Starter solenoid valve should be open when ignition on
8p
ANY AIR RESERVOIR PRESSURE LOW
Step 1
Check reservoir drain valve closed
Close drain valve
Step 2
Check for leaks from reservoir
Repair hoses/connectors, replace tank
Step 3
Check pressure protection valves for correct operation
If one is not opening at set pressure of 85 psi (590 kPa), the tank it serves will not be
charged. Replace, (see para. 4-22)
Step 4
Check pressure gage or pressure switch
Replace as required, (see para. 4-22)
9a
ANY LIGHT FAILS TO OPERATE
Step 1
Check bulb
Replace bulb
Step 2
Check bulb connector
a
Clean
b
Replace connector and bulb if severely corroded
4-41
|