CHAPTER 1
INTRODUCTION
Section I. GENERAL
be used for reporting these improvements. This form
1. Scope
will be completed in triplicate using pencil, pen, or
typewriter. The original and one copy will be forwarded
a. These instructions are published for the use of
direct to the Commanding Officer, U.S. Army Mobility
direct support, general support, and depot maintenance
Equipment  Center,  ATTN:  SMIOME-NMMI,  P.O.
personnel maintaining the Model NM44A1WLF Ward
Drawer 58, St.  Louis, Mo.  63166.  One information
Lafrance Firefighting Truck. They provide information
copy will be provided to the individual's immediate
on the maintenance of the equipment which is beyond
supervisor (e.g., officer, noncommissioned officer,
the scope of the tools, equipment, personnel, or supplies
supervisor, etc.).
normally available to using organizations.
e. Report
all
equipment
improvement
b. Appendix  contains  a  list  of  publications
recommendations as prescribed by TM 38-750.
applicable to this manual. The maintenance allocation
chart is located in the operators and organizational
2. Record and Report Forms
maintenance manual (TM 5-4210-205-12).
For other record and report forms applicable to
c. Numbers in parentheses on illustrations indicate
direct support, general support, and depot maintenance,
quantity. Numbers preceding nomenclature callouts on
refer to TM 38-750.
illustrations  indicate  the  preferred  maintenance
sequence.
Note.  Applicable forms, excluding
standard Form 46 which is carried by
d. The direct reporting by the individual user, of
the operator, will be kept in a canvas
errors, omissions, and recommendations for improving
bag mounted on the equipment.
this manual is authorized and encouraged. DA Form
2028 (Recommended Changes to DA Publications) will
Section II. DESCRIPTION AND DATA
Relief valve regulator limit .....
250 psi (pounds per square
3. Description
inch)
Rated capacity maximum......
500 gpm (gallons per minute)
A general description of the Ward Lafrance Model
Type ....................................
Centrifugal
M44A1WLF Fire-Truck, the location, and the description
Pump ratio ...........................
1 to 2:28
of the identification and instruction plates, and detailed
Shaft diameter .....................
12 in.
description of the components is contained in TM 5-
Taper per foot ......................
1 in.
4210-205-12. The repair and maintenance instructions
are described in appropriate sections of this manual.
c.
Time Standards.
Table 1 lists the
For truck engine and chassis maintenance instructions,
number of man-hours required under normal conditions
refer to TM 9-2320-235-35.
to perform the indicated maintenance and repair for the
firetruck. Components are listed under the appropriate
4. Tabulated Data
functional index. The times listed are not intended to be
rigid  standards.
Under  adverse  conditions,  the
operations will take longer; but under ideal conditions
a. Primer Pump.
with highly skilled mechanics, most of the operations
can be accomplished in considerably less time.
Suction side pipe ..................
in. (inch) (es)
Discharge pipe ......................
1 5/19 in. diameter
b. Water Pump.