Next
ASSEMBLY - continued -820360639
TM 9-1240-375-34&P
0102 00
ASSEMBLY
8
2
5
7
1
4
6
3
1 fc 7 0 4
1.
Position instruction plate (1) on optical instrument housing (2).
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
2.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (3).
3.
Install two new lockwashers (4) (item 9, WP 0145 00) and two machine screws (3).
4.
Position identification plate (5) on optical instrument housing (2).
5.
Apply sealing compound (item 13, WP 0152 00) to threads of two machine screws (6).
6.
Install two new lockwashers (7) (item 9, WP 0145 00) and two machine screws (6).
7.
If removed, install new decal (8).