Azimuth Mechanism 800-mil Steps and Level Travel Inspection
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Azimuth Mechanism 800-mil Steps and Level Travel Inspection - continued -820360614
TM 9-1240-375-34&P
0100 00
4
7
8
5
6
1 fc 6 6 5
3.
Turn azimuth knob (4) until deflection counter (5) reads 3200 mils.
4.
Disengage deflection counter eccentric (6).
5.
Turn azimuth knob (4) until azimuth counter (7) reads 3200 mils.
6.
Disengage azimuth counter eccentric (8).
7.
Turn azimuth knob (4) until vertical reticle line is centered on collimator reticle target.
8.
Engage deflection counter eccentric (6) and azimuth counter eccentric (8).
9
1 fc 6 6 6
9.
Turn elevation knob (9) until horizontal reticle line is centered on collimator reticle target.
0100 00-17