Quantcast DISASSEMBLY - continued -820360589

 

Click here to make tpub.com your Home Page

Page Title: DISASSEMBLY - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
DISASSEMBLY -820360588
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
REPAIR OR REPLACEMENT -820360590
TM 9-1240-375-34&P
0099 00
16.
If damaged or if rotating counter (26) is being replaced, remove headless straight pin (30) and reset
coupling (31).
17.
Remove three machine screws (32), three lockwashers (33), and optical element gear block assembly
(18). Discard lockwashers.
21
23
4
2
3
6
5
1
13
17
16
20
22
8
9
7
24
19
11
10
15
25
14
12
32
33
18
31
30
29
28
26
27
1 fc 6 2 7
CLEANING
WARNING
Use cleaning compound in well-ventilated area away from open flame. Cleaning
compound is harmful to skin and clothing and may give off harmful vapor.
Remove rust, corrosion, dirt, and grease from metal parts. Remove dirt and grease using cleaning compound
(item 10, WP 0152 00).
NOTE
General procedures for cleaning metal parts and optics, removing corrosion, staking
pins, and other procedures are contained in TM 9-254.
0099 00-3

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc.
6230 Stone Rd, Unit Q Port Richey, FL 34668

Phone For Parts Inquiries: (727) 493-0744
Google +