Quantcast Mounting M172/M172A1 Mount on Optical Equipment Test Fixture

 

Click here to make tpub.com your Home Page

Page Title: Mounting M172/M172A1 Mount on Optical Equipment Test Fixture
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Visual Inspection -820360492
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Cross Level Mechanism Backlash Inspection
TM 9-1240-375-34&P
0082 00
5
7
9
6
1
1 fc 5 4 3
8
1 fc 5 4 4
3.
Position mounting bracket (5) on M172/M172A1 mount (1).
4.
Install four bolts (6) to secure mounting bracket (5) to M172/M172A1 mount (1).
5.
Place plate-mounted level (7) parallel to block (8) of shaft on optical equipment test fixture (9).
11
9
11
7
8
10
1 fc 5 4 5
12
1 fc 5 4 6
6.
Turn cant handwheel (10) until bubble (11) in plate-mounted level (7) centers.
7.
Place plate-mounted level (7) 90 degrees to block (8) on optical equipment test fixture (9).
8.
Turn elevation handwheel (12) until bubble (11) in plate-mounted level (7) centers.