ASSEMBLY - continued -820360470
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
REPAIR OR REPLACEMENT -820360472
TM 9-1240-375-34&P
GENERAL SUPPORT
M172/M172A1 TELESCOPE AND QUADRANT MOUNT
(1240-01-037-7290/1240-01-517-2171)
TELESCOPE MOUNTING BRACKET MAINTENANCE
REMOVAL, REPAIR OR REPLACEMENT, INSTALLATION
INITIAL SETUP:
Tools and Special Tools
Shop Set, Instrument and Fire Control: Field Maintenance, Basic Less Power (SC 4931-95-A07)
Tool Kit, Electronic System Maintenance (SC 5180-95-B29)
Materials/Parts
Grease (item 16, WP 0152 00)
Sealing compound (item 13, WP 0152 00)
References
Equipment Conditions
M172/M172A1 telescope and quadrant mount removed from M198/M777 howitzer (TM 9-1025-211-34/
TM 9-1025-215-25&P)
REMOVAL
2
3
4
1
5
1 fc 5 0 5
1.
Loosen socket head capscrew (1) to relieve tension on telescope mounting bracket (2).
2.
Remove four socket capscrews (3) and four flat washers (4).
3.
Lift up and remove telescope mounting bracket (2) from adapter assembly (5).
0078 00-1