INSTALLATION
1
2
3
4
5
6
1 fc 4 0 8
1.
Install two straight pins (1).
NOTE
Ensure mounting adapter is positioned with flat side on top.
2.
Install mounting adapter (2) on bearing housing assembly (3) over two straight pins (1).
3.
Apply sealing compound (item 13, WP 0152 00) to four socket capscrews (4).
4.
Install four new lockwashers (5) (item 2, WP 0124 00) and four socket capscrews (4) and tighten.
5.
Install new lock wire (6) (item 22, WP 0152 00).
END OF WORK PACKAGE