TM 9-1240-375-34&P
0071 00
4
3
5
1 fc 4 0 5
2.
Install rotating eye bracket (3) on two headless straight pins (4) and plunger stud (5).
8
6
7
1 fc 4 0 6
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
3.
Apply sealing compound (item 13, WP 0152 00) to threads of two socket capscrews (6).
4.
Install two new lockwashers (7) (item 21, WP 0123 00) and two socket capscrews (6).
5.
Install new lock wire (8) (item 21, WP 0152 00).
END OF WORK PACKAGE
0071 00-3/4 blank