Quantcast INSTALLATION - continued -820360375

 

Click here to make tpub.com your Home Page

Page Title: INSTALLATION - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
INSTALLATION - continued -820360374
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
INSTALLATION - continued -820360376
TM 9-1240-375-34&P
0069 00
8.
Remove setscrew from knob (9).
9.
Install knob (9).
CAUTION
Support knob in V block on solid surface to prevent damage to worm shaft.
10.
Install headless straight pin (10).
13
12
11
14
1 fc 3 5 5
NOTE
After replacement of V bearing (11) and helical compression spring (12), screw
machine thread plug (13) until V bearing bottoms on worm shaft assembly, and then
back off 1/4 turn.
11.
Apply light coat of grease (item 15, WP 0152 00) on V bearing (11) and install.
12.
Install helical compression spring (12) and machine thread plug (13).
13.
Tighten setscrew (14).
2
9
1 fc 3 5 6
14.
Rotate knob (9) and worm shaft assembly (2) through full travel of gear. Check for binding.
0069 00-7