Quantcast ASSEMBLY - continued -820360356

 

Click here to make tpub.com your Home Page

Page Title: ASSEMBLY - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
ASSEMBLY - continued -820360355
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
ASSEMBLY - continued -820360357
TM 9-1240-375-34&P
0065 00
ASSEMBLY - Continued
86
85
83
84
82
87
1 fc 3 3 2
55.
Install retaining ring (82), protection bellows (83), and retaining ring (84).
56.
Apply sealing compound (item 13, WP 0152 00) to threads of six machine screws (85).
57.
Install six new lockwashers (86) (item 10, WP 0118 00) and six machine screws (85).
58.
Install new lock wire (87) (item 22, WP 0152 00).
92
89
88
93
91
91
88
90
91
6
6
M 171
M 171A 1
1 fc 3 3 3
59.
Install optical instrument support (88) on bearing housing assembly (6).
60.
Apply sealing compound (item 13, WP 0152 00) to setscrew (89) and install to align optical instrument
support (88) (M171A1 only).
61.
If removed or missing, install straight pin (90) (M171A1 only).
62.
Align plain tapered pin(s) (91) on pin holes and drive in.