BEARING HOUSING ASSEMBLY MAINTENANCE
TM 9-1240-375-34&P
0063 00
ASSEMBLY - Continued
6
5
11
8
14
9
15
16
12
10
7
13
17
12
1 fc 2 8 7
2.
Install plate assembly (5) on spacer (6) and secure with two socket capscrews (7).
3.
Position new gasket (8) (item 25, WP 0118 00) on battery enclosure (9).
4.
Carefully connect plate assembly connector (10) to battery enclosure connector (11).
CAUTION
Be careful when assembling components. Do not pinch wire leads or connectors
between parts.
5.
Install battery enclosure (9) on plate assembly (5) with two new lockwashers (12) (item 27,
WP 0118 00) and two screws (13).
6.
Install cap and retainer assembly (14) on battery enclosure (9), using new lockwasher (15) (item 27,
WP 0118 00) and screw (16).
7.
Install battery (17) into battery enclosure (9) and secure with cap and retainer assembly (14).
END OF WORK PACKAGE