Backlash Inspection
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Backlash Inspection - continued -820360292
TM 9-1240-375-34&P
0057 00
1
5
6
1 fc 2 4 8
3.
Scribe index line (5) on M17/M18 or M17A1/M18A1 quadrant (1) near elevation knob (6).
7
1 fc 2 4 9
NOTE
An index pointer may be made from 1/16 in. diameter rod with a sharp point on one
end. The index pointer may be held in place using a small C-clamp (7).
11
12
9
10
5
8
6
1 fc 2 5 0
4.
Place index pointer (8) on the elevation knob (6) directly opposite the scribed index line (5). The index
pointer may have to be moved for each elevation setting.
5.
Place fire control quadrant (9) on top of mounting bracket (10) and level bubble in fire control quadrant
level (11) using micrometer knob (12) and record reading.
0057 00-9