TM 9-1240-375-34&P
0050 00
18
20
2
19
1 fc 1 4 9
M17A1/M18A1 Quadrant
WARNING
Use sealing compound in well-ventilated area away from open flame. Sealing
compound is harmful to skin and clothing and may give off harmful vapor. Exercise
care whenever sealing compound is used.
NOTE
Ensure counters are set to zero and scribe lines on M17A1/M18A1 quadrant housing
assembly are aligned.
18.
Apply sealing compound (item 13, WP 0152 00) to threads of three machine screws (18).
19.
Position counter assembly (19) in housing assembly (2) and secure with three new lockwashers (20)
(item 19, WP 0112 00) and three machine screws (18).
2
21
22
1 fc 1 5 0
M17A1/M18A1 Quadrant
20.
Check to ensure counters (21) are zeroed, with scribe lines on base assembly (22) and housing assembly
(2) aligned.
0050 00-13