Quantcast CLEANING -820360203

 

Click here to make tpub.com your Home Page

Page Title: CLEANING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
DISASSEMBLY - continued -820360202
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
ASSEMBLY -820360204
TM 9-1240-375-34&P
0049 00
NOTE
Note position of flat (43) on worm shaft assembly (35) in relationship to housing
assembly (3).
25.
Rotate and remove worm shaft assembly (35) from housing assembly (3).
NOTE
For maintenance of the fire control level (cross level vial) on the M18 quadrant, refer
CLEANING
WARNING
Use cleaning compound in well-ventilated area away from open flame. Cleaning
compound is harmful to skin and clothing and may give off harmful vapor.
Clean all parts with cleaning compound (item 12, WP 0152 00). Wipe off excess cleaning compound with a
clean wiping rag (item 18, WP 0152 00).
REPAIR OR REPLACEMENT
1.
Inspect gears for missing teeth and stripped gears.
2.
Inspect bearing surfaces for nicks and burrs.
3.
Repair is by replacement of authorized parts that do not meet inspection criteria. Refer to WP 0111 00
ASSEMBLY
NOTE
The following steps are written and illustrated for the M17 quadrant but also apply
to the M18 quadrant.
1
2
1 fc 1 1 1
M17/M18 Quadrant
1.
Apply a light coat of grease (item 15, WP 0152 00) to worm shaft assembly (1).