0049 00
DISASSEMBLY - Continued
15
16
17
14
1 fc 0 9 9
M17/M18 Quadrant
8.
Remove adjusting plate (14).
9.
Loosen setscrew (15) and cushioning pad (16).
10.
Loosen setscrew (17).
19
18
1 fc 1 0 0
M17/M18 Quadrant
NOTE
Replacement of fire control level assembly parts can be done without removing fire
control level assembly from M17/M18 quadrant.
11.
Drive out headless straight pin (18).
12.
Lift off fire control level assembly (19) and remove sealing compound.