Quantcast Table 1. Direct Support Troubleshooting Procedures. -820360052

 

Click here to make tpub.com your Home Page

Page Title: Table 1. Direct Support Troubleshooting Procedures.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
TROUBLESHOOTING PROCEDURES FIRE CONTROL LEVEL ASSEMBLY -820360051
Up
TM-9-1240-375-34-P Quadrant Fire Control: M17 (1290-01-037-3883) and M17A1 (1290-01-515-8260); Mount Telescope and Quadrant: M171 (1240-01-039-7273) Manual
Next
Table 1. Direct Support Troubleshooting Procedures - continued -820360053
TM 9-1240-375-34&P
0006 00
FIRE CONTROL LEVEL ASSEMBLY - Continued
Table 1. Direct Support Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1
1
2
3
3
4
4
1 fc 0 2 1
1 fc 0 2 2
M17A1 Quadrant
M18A1 Quadrant
1. ELEVATION LEVEL VIAL
Observe visually in darkened
1. Cycle ON/OFF pushbutton
(1), CROSS LEVEL VIAL (2),
area.
switch.
AND COUNTER DIALS (3)
a. Press red push-button
HAVE NO ILLUMINATION.
switch on battery
enclosure.
NOTE
Switch has an approximate
three-second delay.
b. Wait approximately three
seconds and check if light-
emitting diode (LED) light
sources are ON/OFF.
c. Repeat above steps until
assured of correct
operation.
2. Check for proper battery
installation (same as diagram
on battery enclosure).
0006 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc.
6230 Stone Rd, Unit Q Port Richey, FL 34668

Phone For Parts Inquiries: (727) 493-0744
Google +