TM 55-1925-292-14&P
0028 00
8. Slide the motor coupling flange (figure 3, item 2) towards the AFFF pump motor (figure 3, item 3).
9. Remove the four bolts (figure 3, item 4), four lockwashers (figure 3, item 5), and four flat washers (figure 3,
item 6). Discard the four lockwashers.
WARNING
Heavy loads can crush. Do not allow any body parts to come under the load or
between the load and a stationary object. Death or serious injury can result.
10. Use a sling and chain hoist to remove the AFFF pump motor (figure 3, item 3) from its foundation.
11. Slide the motor coupling flange (figure 3, item 2) off the motor shaft (figure 3, item 7).
3
2
1
8
7
4
5
6
Figure 3. AFFF Pump Coupling Detail
0028 00-3