Quantcast AERIAL DISCHARGE VALVE DOES NOT CLOSE WITH PANEL SWITCH

Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: AERIAL DISCHARGE VALVE DOES NOT CLOSE WITH PANEL SWITCH
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
EMERGENCY  HYDRAULIC  POWER  LIGHT  WILL  NOT  ILLUMINATE  ON  AERIAL  PANEL  WHEN EMERGENCY PUMP IS ACTIVATED
Up
TM-5-4210-233-14P-1 Twin Agent 4x4 Firefighting Truck Model No. CM-KFT-B Manual
Next
LADDER INTERCOM DOES NOT FUNCTION PROPERLY
TM 5-4210-233-14&P-1 4-2.  Unit Troubleshooting-Continued MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION ELECTRICAL SYSTEM - AERIAL CONTROL PANEL - Continued 10 AERIAL DISCHARGE VALVE DOES NOT CLOSE WITH PANEL SWITCH - Continued Step 4.  Check wiring for continuity. Replace wire (see para 4-9.4). Step 5.  Refer to "+12 volts not present at aerial master buss" troubleshooting procedure." Step 6.  Refer to "turntable swivel assembly slip ring contact interrupted" troubleshooting procedure. 11 AUDIO ALARM DOES NOT FUNCTION (Refer to Electrical Wiring Diagrams, Appendix H, Sheets 11 and 12 of 16.) Step 1.  Check switch for proper operation. Replace switch (see para 4-9.4). Step 2.  Check alarm sounds when 12V is applied across terminals. Replace alarm (see para 4-9.4). Step 3.  Check aerial circuit breaker#4 for +12V. Replace circuit breaker (see para 4-99). Step 4.  Check wiring for continuity. Replace wire (see para 4-9.4). Step 5.  Refer to "swivel assembly slip ring contact interrupted" troubleshooting procedure. Step 6.  Refer to "aerial circuit +12 volts not present at aerial master buss" troubleshooting procedure. 12 LADDER INTERCOM DOES NOT FUNCTION PROPERLY (Refer to Electrical Wiring Diagrams, Appendix H, Sheet 11 of 16.) Step 1   Check for +12V at circuit breaker #6 with aerial master circuit on. Replace breaker (see para 4-99). Step 2.  Check for +12V at aerial panel intercom unit on wire #1237. Replace wire from breaker (see para 4-9.4). 4-134