5-14. STARTER REPAIR AND TESTING - Continued
(37)
Install preformed packing (68) in lever
housing (45).
(38)
Press bushing (69) into drive housing
(70).
(39)
Install six rubber balls (71) into drive
housing
(40)
Soak felt wick (72) with oil and install.
(41)
Install cup plug (73).
(42)
Install starter drive (74) in shift lever
(54) in lever housing (45).
(43)
Align match marks and install drive
housing (70) on lever housing (45) with
five long screws (75) and one short
screw (76). Torque screws to 15 lb ft
(20 N.m).