5-12. STARTER MOTOR - Continued
b. Installation.
(1)
If necessary, remove three screws (13) from back of starter motor and install bracket (2) with screws
(1 3). Use holes "A", "B" and "C" when mounting bracket (2) to starter motor. Hole "C" should align
with brush cap "F" on starter motor.
(2)
Install new gasket (9) on face of starter (8).
(3)
Slide starter (8) into flywheel housing to engage starter drive with flywheel ring gear.
(4)
Hold starter in position and install three lockwashers (1O) and screws (11) to secure starter. Torque
screws to 137-147 ft lb (186-200 Nm).
(5)
Install two screws (1) and flat washers (12) through holes "D" and "E" of bracket 2. Install spacers (3),
lockwashers (5) and nuts (7).
(6)
Using tags for identification, connect engine harness wires to starter motor ground terminal (1 4) and
solenoid BATTERMINAL (15).
c.
Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
5-63