Quantcast AERIAL LADDER ELECTRICAL CABLES -706880645

 

Click here to make tpub.com your Home Page

Page Title: AERIAL LADDER ELECTRICAL CABLES
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Adjustment-continued
Up
TM-5-4210-233-14-P-1 Firfighting Truck 100 Ft. Aerial Ladder 1000 GPM Manual
Next
AUXILIARY POWER UNIT (APU) -706880646
TM 5-4210-233-14&P-1
4-206. AERIAL LADDER ELECTRICAL CABLES
This task covers:
a. Adjustment
b. Follow-on Maintenance
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12 .)
(Appendix B, Section III, Item 1)
APU Shutdown (see para 2-16 .)
Batteries Disconnected (see para 4-114 .)
a. Adjustment.
CAUTION
Proper spring tension on electrical cables must be checked
and inspected after the extension/retraction cables are
checked. Failure to maintain proper tension can result in
damage to cables.
(1) Measure the distance (A) between the strut and spring stop washer.
(2) The measurement should be 4-1/8 inches (105 mm).
(3) Adjust nut to increase or decrease spring tension.
b. Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
4-516

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc.
6230 Stone Rd, Unit Q Port Richey, FL 34668

Phone For Parts Inquiries: (727) 493-0744
Google +